1. Precise and reliable
Careful design, rigorous laboratory testing, and comprehensive quality control to ensure that the unit has excellent reliability;
Parts of the world-renowned brands, ensuring high reliability and service life;
Intelligent microprocessor control system, which enables the unit is always running at its best.
2. Constant temperature and humidity
It can accurately control the temperature (accuracy ± 1 ° C), humidity (± 5%) to adapt to all-day job requirements;
The unit equipped with a frontal area of the evaporator, to reflect the amount of wind, the small enthalpy difference, to produce the greatest sensible cooling capacity, so that the indoor environment, easy to maintain the equilibrium of temperature and humidity;
3. Variety of options
The GT-HF series of standard temperature and humidity air-conditioning unit, with conventional constant temperature and humidity control is flexible, applicable to the general (conventional) constant temperature and humidity requirements of the occasion;
GT-the HFD series of ceiling temperature and humidity air conditioning units, can be installed on the ceiling applies to the room space is small or there is no dedicated room small-scale temperature and humidity region of space;
GT-the HFM family room precision air conditioning units, communication base stations, telecommunications rooms, data center temperature and humidity control accuracy and operational stability have very high requirements of the occasion;
The GT-HFJ series Purification constant temperature and humidity air conditioning units, an increase of the purification function, applicable to the purification occasions such as medical operating rooms, electronic workshop;
Non-standard series, to provide customers with the most satisfactory products. For example: The ultra-high precision (precision of temperature control ± 0.3 ° C, humidity control accuracy of ± 2%); Heating, humidification form; Cryogenic temperature and humidity, or large temperature difference between temperature and constant temperature and humidity; Long piping, ultra-high hydrostatic; Integrated design, waste heat recovery.
4. Other features
Variety back to the wind (on the air: The hood /Â duct or directly from the unit at the top of the air; Under the air: And sent to all parts of the engine room through the raised floor plenum chamber);
Configure the removable electrode humidifier, quickly produce clean steam, optional electric humidifier scene according to user requirements;
G4 level of air filters, filter effects, to meet the conventional cleanliness requirements, and can be equipped with higher cleanliness of the F8-level air filter;
Tubular stainless steel electric heating or PTC electric heating, high heating efficiency, to increase the power to adapt to the use of the alpine region, multiple protection so that the heating is more safe and reliable;
Â
GT-HFM series constant temperature and humidity precision air conditioner specification
Model GT-HFM-()
35
40
50
55
60
70
80
90
Specification
Total cooling capacity
kW
36.5
42.1
49.1
54.1
61
71.6
81.4
93.6
Sensible cooling capacity
kW
33.8
38.4
44.3
49.8
55.5
65.1
74.7
85.1
Electric heating
kW
15
18
18
18
24
24
30
30
Air volume 2*
m3/h
10500
11500
13000
15500
18000
20500
22000
25000
Outlet air pressure 2*
Pa
75
75
75
75
100
100
125
125
Noise 3*
dB(A)
56
58
58
58
58
58
60
60
Temperature control range and accuracy
° C
18~28, ± 1
Humidity control range and accuracy
%
45~70, ± 5
Power
3N-380V-50Hz
Input power 4*
kW
30
38.2
39.6
40.7
52.3
56.7
66.8
74.8
Indoor unit
Supply air fan
type
low noise centrifugal type
capacity
kW
2.2
3
3
4
5.5
7.5
7.5
11
Electrode humidifier
humidification volume
kg/h
13
13
13
15
15
15
18
21
Electric heating
capacity
kW
15
18
18
18
24
24
30
30
Evaporator type
Inner grooved copper tube and aluminum fin
Air filter
primary efffect plate type filter
Dimension
L
mm
1800
1800
2000
2000
2000
2200
2200
2500
W
mm
850
850
850
850
850
1080
1080
1200
H
mm
2200
2200
2150
2150
2150
2350
2350
2450
Weight
kg
580
610
710
750
820
900
980
1250
Outdoor unit
Model GT-( )*quantity
#####
WL40*1
#####
WL55*1
WL60*1
WL70*1
WL40*2
WL50*2
compressor
type
Totally enclosed scroll type
quantity
1
2
2
2
2
2
4
4
condenser type
Inner grooved copper tube and aluminum fin
Condensing fan
type
Low noise axial type
capacity
kW
0.75
0.55*2
0.55*2
0.55*2
0.75*2
0.75*2
0.55*4
0.55*4
Dimension
L
mm
980
1880
1880
1880
1880
1880
1880
1880
W
mm
980
980
980
980
980
980
980
980
H
mm
1234
1080
1080
1080
1234
1234
1080
1080
Weight
kg
250
320
400
400
450
500
320*2
400*2
Freon 5*
type
R22(R407C/R410A)
control method
Out balance expansion valve
Collecting pipe 6*
liquid pipe`s diameter
mm
15.88 (12.7)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*4 (12.7*4)
15.88*4 (12.7*4)
gas pipe`s diameter
mm
34.9 (28.6)
22.23*2 (19.05*2)
28.6*2 (22.23*2)
28.6*2 (22.23*2)
28.6*2 (22.23*2)
34.9*2 (28.6*2)
22.23*4 (19.05*4)
28.6*4 (22.23*4)
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
1. Cooling condition: Indoor dry bulb/wet bulb: 24/17° C; Outdoor dry bulb/wet bulb: 35/24° C;
2. Air volume\static pressure are standard data, it can be designed by client
Â
3. Noise data is measured 3Â meters far away from the units
Â
Â
Â
Â
4. The input power means the power consumption under max condtion
Â
Â
Â
5. If freon is R410A or R407C, please noted it in the order
Â
Â
Â
Â
6. The dimension in the brackets is for R410A`s collecting pipe
Â
Â
Â
AIR CONDITIONING SYSTEM OF PRECISION
1. Precise and reliable
Careful design, rigorous laboratory testing, and comprehensive quality control to ensure that the unit has excellent reliability;
Parts of the world-renowned brands, ensuring high reliability and service life;
Intelligent microprocessor control system, which enables the unit is always running at its best.
2. Constant temperature and humidity
It can accurately control the temperature (accuracy ± 1 ° C), humidity (± 5%) to adapt to all-day job requirements;
The unit equipped with a frontal area of the evaporator, to reflect the amount of wind, the small enthalpy difference, to produce the greatest sensible cooling capacity, so that the indoor environment, easy to maintain the equilibrium of temperature and humidity;
3. Variety of options
The GT-HF series of standard temperature and humidity air-conditioning unit, with conventional constant temperature and humidity control is flexible, applicable to the general (conventional) constant temperature and humidity requirements of the occasion;
GT-the HFD series of ceiling temperature and humidity air conditioning units, can be installed on the ceiling applies to the room space is small or there is no dedicated room small-scale temperature and humidity region of space;
GT-the HFM family room precision air conditioning units, communication base stations, telecommunications rooms, data center temperature and humidity control accuracy and operational stability have very high requirements of the occasion;
The GT-HFJ series Purification constant temperature and humidity air conditioning units, an increase of the purification function, applicable to the purification occasions such as medical operating rooms, electronic workshop;
Non-standard series, to provide customers with the most satisfactory products. For example: The ultra-high precision (precision of temperature control ± 0.3 ° C, humidity control accuracy of ± 2%); Heating, humidification form; Cryogenic temperature and humidity, or large temperature difference between temperature and constant temperature and humidity; Long piping, ultra-high hydrostatic; Integrated design, waste heat recovery.
4. Other features
Variety back to the wind (on the air: The hood /Â duct or directly from the unit at the top of the air; Under the air: And sent to all parts of the engine room through the raised floor plenum chamber);
Configure the removable electrode humidifier, quickly produce clean steam, optional electric humidifier scene according to user requirements;
G4 level of air filters, filter effects, to meet the conventional cleanliness requirements, and can be equipped with higher cleanliness of the F8-level air filter;
Tubular stainless steel electric heating or PTC electric heating, high heating efficiency, to increase the power to adapt to the use of the alpine region, multiple protection so that the heating is more safe and reliable;
Â
GT-HFM series constant temperature and humidity precision air conditioner specification
Model GT-HFM-()
35
40
50
55
60
70
80
90
Specification
Total cooling capacity
kW
36.5
42.1
49.1
54.1
61
71.6
81.4
93.6
Sensible cooling capacity
kW
33.8
38.4
44.3
49.8
55.5
65.1
74.7
85.1
Electric heating
kW
15
18
18
18
24
24
30
30
Air volume 2*
m3/h
10500
11500
13000
15500
18000
20500
22000
25000
Outlet air pressure 2*
Pa
75
75
75
75
100
100
125
125
Noise 3*
dB(A)
56
58
58
58
58
58
60
60
Temperature control range and accuracy
° C
18~28, ± 1
Humidity control range and accuracy
%
45~70, ± 5
Power
3N-380V-50Hz
Input power 4*
kW
30
38.2
39.6
40.7
52.3
56.7
66.8
74.8
Indoor unit
Supply air fan
type
low noise centrifugal type
capacity
kW
2.2
3
3
4
5.5
7.5
7.5
11
Electrode humidifier
humidification volume
kg/h
13
13
13
15
15
15
18
21
Electric heating
capacity
kW
15
18
18
18
24
24
30
30
Evaporator type
Inner grooved copper tube and aluminum fin
Air filter
primary efffect plate type filter
Dimension
L
mm
1800
1800
2000
2000
2000
2200
2200
2500
W
mm
850
850
850
850
850
1080
1080
1200
H
mm
2200
2200
2150
2150
2150
2350
2350
2450
Weight
kg
580
610
710
750
820
900
980
1250
Outdoor unit
Model GT-( )*quantity
#####
WL40*1
#####
WL55*1
WL60*1
WL70*1
WL40*2
WL50*2
compressor
type
Totally enclosed scroll type
quantity
1
2
2
2
2
2
4
4
condenser type
Inner grooved copper tube and aluminum fin
Condensing fan
type
Low noise axial type
capacity
kW
0.75
0.55*2
0.55*2
0.55*2
0.75*2
0.75*2
0.55*4
0.55*4
Dimension
L
mm
980
1880
1880
1880
1880
1880
1880
1880
W
mm
980
980
980
980
980
980
980
980
H
mm
1234
1080
1080
1080
1234
1234
1080
1080
Weight
kg
250
320
400
400
450
500
320*2
400*2
Freon 5*
type
R22(R407C/R410A)
control method
Out balance expansion valve
Collecting pipe 6*
liquid pipe`s diameter
mm
15.88 (12.7)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*2 (12.7*2)
15.88*4 (12.7*4)
15.88*4 (12.7*4)
gas pipe`s diameter
mm
34.9 (28.6)
22.23*2 (19.05*2)
28.6*2 (22.23*2)
28.6*2 (22.23*2)
28.6*2 (22.23*2)
34.9*2 (28.6*2)
22.23*4 (19.05*4)
28.6*4 (22.23*4)
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
1. Cooling condition: Indoor dry bulb/wet bulb: 24/17° C; Outdoor dry bulb/wet bulb: 35/24° C;
2. Air volume\static pressure are standard data, it can be designed by client
Â
3. Noise data is measured 3Â meters far away from the units
Â
Â
Â
Â
4. The input power means the power consumption under max condtion
Â
Â
Â
5. If freon is R410A or R407C, please noted it in the order
Â
Â
Â
Â
6. The dimension in the brackets is for R410A`s collecting pipe
Â
Â
Â