Double Stage Water-Ring Vacuum Pump Used in Medicine Industry

Model NO.: 2SK-25
Motor Power: 55kw, 45kw
Rotating Speed: 980rpm
Water Supply: 60-110L/Min
Inlet&Outlet Dimensions: 100mm
Weight: 926kg
Trademark: DVE
Transport Package: Neutral Wooden Case
Specification: CE MARK, ABB MOTOR, SPARE PARTS OF HIGH LEVEL
Origin: Zhejiang, Cn
HS Code: 8414100090
Model NO.: 2SK-25
Motor Power: 55kw, 45kw
Rotating Speed: 980rpm
Water Supply: 60-110L/Min
Inlet&Outlet Dimensions: 100mm
Weight: 926kg
Trademark: DVE
Transport Package: Neutral Wooden Case
Specification: CE MARK, ABB MOTOR, SPARE PARTS OF HIGH LEVEL
Origin: Zhejiang, Cn
HS Code: 8414100090

SPECIFICATION

Products Name: Water Ring Vacuum Pump


PS: Detailed model refer to REAL PIECE pls.

WORKING THEORY
1. Series SK,2SK Water Ring Vacuum Pumps can be used to exhaust ordinary gases as well as condensable gases(such as water vapor). Because they have the features of isothermal compression, they can exhaust flammable and explosive gases. When the pump made up of anti-corrosion material is selected, it can be used for exhausting corrosive gases too. 
 
   2SK series two-stage liquid ring vacuum pumps can work well like two sets of SK series water ring vacuum pump. Due to SK series vacuum pumps only reach the maximum vacuum of-700mmHg, to meet the high vacuum and the large pumping speed under high vacuum, China developed the 2SK series water ring vacuum pump in 80s in the 20th century. 
 
2. Series 2YK Liquid Ring Vacuum Pumps have the features of higher vacuum and better applicability. The different types of gases can be pumped with the selected suitable working media. Therefore, they can be applied in wider range.
 
3. The pumps run smoothly with low noise and consumption. The energy-saving is 30 percent comparing with the Water Jet and the Water VaporJet Pumps.
 
 Double Stage Water-Ring Vacuum Pump Used in Medicine Industry


Double Stage Water-Ring Vacuum Pump Used in Medicine Industry
  

ADVANTAGE

1. Compared with SK water vacuum pump ,It gets high vacuum and pumping speed etc..
2. Simple structure and easy maintenance.
3. The mostly working medium is water and low maintenance costs.
4.The pump is widely use in many areas and suction water vapor,flammable, explosive and various gases contain a small amount of dust and liquid.
5. The pump can works in the harsh condition

PARAMETER

Model Displacement
(m3/min)
Ultimate Pressure
hPa     Torr
Motor Power
 (kW)
Rotating Speed
(rpm)
Water Supply
(L/min)
Inlet&Outlet 
Dimensions (mm)
Weight
(kg)
SK-0.5B 0.5 47     35 1.5 2900 8 25 45
SK-0.8 0.8 47     35 2.2 2900 10 40 60
SK-1.5 1.5 47     35 4 2900 15 40 75
SK-3 3 80     60  5.5 1450 25 50 153
SK-6 6 80     60  11 1450 35 50 210
SK-12 12 80     60  22 980 70 100 600
SK-12B 12 80     60  18.5 980 60 100 450
SK-25 25 80     60  45 980 70 100 900
SK-30 30 80     60  55 980 75 100 1200
SK-42 42 80     60 75 740 100 100 1500
2SK-2B 2 40     30 5.5 1450 20 50 185
2YK-2B 2 6.6    5 5.5 1450 20 50 185
2SK-3 3 40     30 7.5 1450 25 50 320
2YK-3 3 6.6    5 7.5 1450 25 50 320
2SK-6B 6 33     30 11 1450 35 50 370
2YK-6B 6 6.6    5 11 1450 35 50 370
2SK-12 12 33     25 22 980 70 80 850
2YK-12 12 6.6    5 22 980 70 80 850
2SK-25 25 33     25 55,45 980 60-110 100 926


CURVE

Double Stage Water-Ring Vacuum Pump Used in Medicine Industry

 

ADVANTAGE

1. Compared with SK water vacuum pump ,It gets high vacuum and pumping speed etc..
2. Simple structure and easy maintenance.
3. The mostly working medium is water and low maintenance costs.
4.The pump is widely use in many areas and suction water vapor,flammable, explosive and various gases contain a small amount of dust and liquid.
5. The pump can works in the harsh condition

Double Stage Water-Ring Vacuum Pump Used in Medicine Industry

Double Stage Water-Ring Vacuum Pump Used in Medicine Industry

Regular Selection for Water(Liquid)Ring Vacuum Pump


1,Based on the vacuum value
(1)If the pump is operated for long time with the inlet pressure range between1.3×104~1×105Pa (between 100 and 760 Torr), please choose series SK Water Ring Vacuum Pump.
(2)If the pump is operated for long time with the inlet pressure range between5×103~1.3×104Pa(between40 and 100 Torr), please choose series 2SK Water Ring Vacuum Pump.
(3)If the pump is operated for long time with the inlet pressure range between1×103~1.3×104Pa(between8 and 100 Torr), please choose series 2YK Liquid Ring Vacuum Pump.

2,Working Media 
There are four principles to choose working media(i.e.ring liquids);
(1) Lower saturated steam pressure
(2) Lower viscosity
(3) Stable physical & chemical features; no chemical reaction with the pumped gas;no corrosion to the pump; no pollution to the environment.
(4) Economy

      If the water is selected as the working medium, the best temperature of supply water should be lower than or equal to 15 °C; the highest one should not be higher than 40°C. While the transformer oil or other low viscosity and saturated vapor pressure industrial oils are as the working media, the general supply temperature should not higher than 40°C and the working media temperature inside the pump chamber should not be higher than 60C, when the liquid with lower boiling point is selected as the working media under some special circumstances, the cooling unit must be equipped to cool down the working media in order to ensure that the max temperature is 30ºC-50ºC, lower than the boiling point. For the closed circulated system of working media, the liquid storage unit and cooler must be equipped, and the gas-liquid separator must be installed at outlet. The mechanical seal should be used for dynamic seal of the shaft.

3,Choose the dynamic seal of the shaft:
Choose the packing seal in general occasion; choose the mechanical seal when the pump is used in no leak occasion.

4,Choose the material of the part that the gas passed:

(1) For the non anti-corrosion pump, the shaft is made of 45#steel or 40Cr, other parts are made of cast Iron or brass;
(2) For the anti-corrosion pump,the parts that the gas passed, should be made of stainless steel 304 and 306, or other material suitable for the respectively corrosive gas, or the parts should be put with anti-corrosion coating.


5, The motor should be selected based on pumping pressure.

If the pump is used for vacuuming while transferring gas, the pressure of pump outlet exceeds the standard atmosphere pressure.
When the outlet pressure exceeds 0.15MPa, the special double-stages liquid ring compressor should be chosen and not the vacuum pump refitted. Tthe power of the equipped motor should be increased obviously. And the special gas-liquid separator and auto-drain unit should be equipped too.
When the outlet pressure is below 0.15MPa, it can use the vacuum pump refitted as compressor. The power of the equipped motor should be increased properly.


6,Composition methods of the water ring vacuum pump system
The opening circulation system should be used if the working liquid in the outlet need not be circulated or partially circulated.
The closed circulation system should be used if the working liquid in the outlet must be circulated.
Double Stage Water-Ring Vacuum Pump Used in Medicine Industry


APPLICATIONS
Widely used in papermaking, chemical, petrochemical, light industry, pharmaceutical, food, building materials, electrical appliances, coal washing and  mineral dressing industry, fertilizer, etc. 
 
In the coal industry, it can especially pump highly flammable and explosive gas, such as mash gas, methane, can design installation of ground gas drainage station, can form a complete set of mobile gas drainage system.
 
WE CAN PROVIDE YOU
1. On-time Delivery, with More Choice 
2. Perfect Technical Support
3. Customized Vacuum Solutions and Service 
4. Samples Available
5.  Long Quality Guarantee 
6. Fast Response to Customers' Feedback in 12 hours 
 
DVE SERVICE
Sea Port: Ningbo/Shanghai, China
Standard: CE Mark, Spare Parts Of High Level
Delivery: Normally according to our factory production schedule, but we can follow your first order time 
Warranty: If pump appear quality problems, free replacements of spare parts will be offered within one year
 
DEVELOPMENT VACUUM EQUIPMENT CO., LTD 
ADD:DONGGANG INDZONE, TAIZHOU, ZHEJIANG, CHINA PC: 317106
TEL:+86-576-83598308 FAX:+86-576-83598309 

SPECIFICATION

Products Name: Water Ring Vacuum Pump


PS: Detailed model refer to REAL PIECE pls.

WORKING THEORY
1. Series SK,2SK Water Ring Vacuum Pumps can be used to exhaust ordinary gases as well as condensable gases(such as water vapor). Because they have the features of isothermal compression, they can exhaust flammable and explosive gases. When the pump made up of anti-corrosion material is selected, it can be used for exhausting corrosive gases too. 
 
   2SK series two-stage liquid ring vacuum pumps can work well like two sets of SK series water ring vacuum pump. Due to SK series vacuum pumps only reach the maximum vacuum of-700mmHg, to meet the high vacuum and the large pumping speed under high vacuum, China developed the 2SK series water ring vacuum pump in 80s in the 20th century. 
 
2. Series 2YK Liquid Ring Vacuum Pumps have the features of higher vacuum and better applicability. The different types of gases can be pumped with the selected suitable working media. Therefore, they can be applied in wider range.
 
3. The pumps run smoothly with low noise and consumption. The energy-saving is 30 percent comparing with the Water Jet and the Water VaporJet Pumps.
 
 Double Stage Water-Ring Vacuum Pump Used in Medicine Industry


Double Stage Water-Ring Vacuum Pump Used in Medicine Industry
  

ADVANTAGE

1. Compared with SK water vacuum pump ,It gets high vacuum and pumping speed etc..
2. Simple structure and easy maintenance.
3. The mostly working medium is water and low maintenance costs.
4.The pump is widely use in many areas and suction water vapor,flammable, explosive and various gases contain a small amount of dust and liquid.
5. The pump can works in the harsh condition

PARAMETER

Model Displacement
(m3/min)
Ultimate Pressure
hPa     Torr
Motor Power
 (kW)
Rotating Speed
(rpm)
Water Supply
(L/min)
Inlet&Outlet 
Dimensions (mm)
Weight
(kg)
SK-0.5B 0.5 47     35 1.5 2900 8 25 45
SK-0.8 0.8 47     35 2.2 2900 10 40 60
SK-1.5 1.5 47     35 4 2900 15 40 75
SK-3 3 80     60  5.5 1450 25 50 153
SK-6 6 80     60  11 1450 35 50 210
SK-12 12 80     60  22 980 70 100 600
SK-12B 12 80     60  18.5 980 60 100 450
SK-25 25 80     60  45 980 70 100 900
SK-30 30 80     60  55 980 75 100 1200
SK-42 42 80     60 75 740 100 100 1500
2SK-2B 2 40     30 5.5 1450 20 50 185
2YK-2B 2 6.6    5 5.5 1450 20 50 185
2SK-3 3 40     30 7.5 1450 25 50 320
2YK-3 3 6.6    5 7.5 1450 25 50 320
2SK-6B 6 33     30 11 1450 35 50 370
2YK-6B 6 6.6    5 11 1450 35 50 370
2SK-12 12 33     25 22 980 70 80 850
2YK-12 12 6.6    5 22 980 70 80 850
2SK-25 25 33     25 55,45 980 60-110 100 926


CURVE

Double Stage Water-Ring Vacuum Pump Used in Medicine Industry

 

ADVANTAGE

1. Compared with SK water vacuum pump ,It gets high vacuum and pumping speed etc..
2. Simple structure and easy maintenance.
3. The mostly working medium is water and low maintenance costs.
4.The pump is widely use in many areas and suction water vapor,flammable, explosive and various gases contain a small amount of dust and liquid.
5. The pump can works in the harsh condition

Double Stage Water-Ring Vacuum Pump Used in Medicine Industry

Double Stage Water-Ring Vacuum Pump Used in Medicine Industry

Regular Selection for Water(Liquid)Ring Vacuum Pump


1,Based on the vacuum value
(1)If the pump is operated for long time with the inlet pressure range between1.3×104~1×105Pa (between 100 and 760 Torr), please choose series SK Water Ring Vacuum Pump.
(2)If the pump is operated for long time with the inlet pressure range between5×103~1.3×104Pa(between40 and 100 Torr), please choose series 2SK Water Ring Vacuum Pump.
(3)If the pump is operated for long time with the inlet pressure range between1×103~1.3×104Pa(between8 and 100 Torr), please choose series 2YK Liquid Ring Vacuum Pump.

2,Working Media 
There are four principles to choose working media(i.e.ring liquids);
(1) Lower saturated steam pressure
(2) Lower viscosity
(3) Stable physical & chemical features; no chemical reaction with the pumped gas;no corrosion to the pump; no pollution to the environment.
(4) Economy

      If the water is selected as the working medium, the best temperature of supply water should be lower than or equal to 15 °C; the highest one should not be higher than 40°C. While the transformer oil or other low viscosity and saturated vapor pressure industrial oils are as the working media, the general supply temperature should not higher than 40°C and the working media temperature inside the pump chamber should not be higher than 60C, when the liquid with lower boiling point is selected as the working media under some special circumstances, the cooling unit must be equipped to cool down the working media in order to ensure that the max temperature is 30ºC-50ºC, lower than the boiling point. For the closed circulated system of working media, the liquid storage unit and cooler must be equipped, and the gas-liquid separator must be installed at outlet. The mechanical seal should be used for dynamic seal of the shaft.

3,Choose the dynamic seal of the shaft:
Choose the packing seal in general occasion; choose the mechanical seal when the pump is used in no leak occasion.

4,Choose the material of the part that the gas passed:

(1) For the non anti-corrosion pump, the shaft is made of 45#steel or 40Cr, other parts are made of cast Iron or brass;
(2) For the anti-corrosion pump,the parts that the gas passed, should be made of stainless steel 304 and 306, or other material suitable for the respectively corrosive gas, or the parts should be put with anti-corrosion coating.


5, The motor should be selected based on pumping pressure.

If the pump is used for vacuuming while transferring gas, the pressure of pump outlet exceeds the standard atmosphere pressure.
When the outlet pressure exceeds 0.15MPa, the special double-stages liquid ring compressor should be chosen and not the vacuum pump refitted. Tthe power of the equipped motor should be increased obviously. And the special gas-liquid separator and auto-drain unit should be equipped too.
When the outlet pressure is below 0.15MPa, it can use the vacuum pump refitted as compressor. The power of the equipped motor should be increased properly.


6,Composition methods of the water ring vacuum pump system
The opening circulation system should be used if the working liquid in the outlet need not be circulated or partially circulated.
The closed circulation system should be used if the working liquid in the outlet must be circulated.
Double Stage Water-Ring Vacuum Pump Used in Medicine Industry


APPLICATIONS
Widely used in papermaking, chemical, petrochemical, light industry, pharmaceutical, food, building materials, electrical appliances, coal washing and  mineral dressing industry, fertilizer, etc. 
 
In the coal industry, it can especially pump highly flammable and explosive gas, such as mash gas, methane, can design installation of ground gas drainage station, can form a complete set of mobile gas drainage system.
 
WE CAN PROVIDE YOU
1. On-time Delivery, with More Choice 
2. Perfect Technical Support
3. Customized Vacuum Solutions and Service 
4. Samples Available
5.  Long Quality Guarantee 
6. Fast Response to Customers' Feedback in 12 hours 
 
DVE SERVICE
Sea Port: Ningbo/Shanghai, China
Standard: CE Mark, Spare Parts Of High Level
Delivery: Normally according to our factory production schedule, but we can follow your first order time 
Warranty: If pump appear quality problems, free replacements of spare parts will be offered within one year
 
DEVELOPMENT VACUUM EQUIPMENT CO., LTD 
ADD:DONGGANG INDZONE, TAIZHOU, ZHEJIANG, CHINA PC: 317106
TEL:+86-576-83598308 FAX:+86-576-83598309 

LINA Intermeshing Dispersion Kneader Mixer

Intermeshing type is one of kneader mixer's rotor types and it is different with tangential rotors. In kneader machines, the rotor must be driven by a constant speed connecting gear, the large diameter of one rotor interacts with the small diameter of the opposite. There are ridges on the rotor, the ridges are helically shaped along the rotor to allow the mixing material to move axially within the mixing chamber. Dispersion mixing is mainly carried out in a small gap between two sizes of rotors.


Intermeshing Dispersion Kneader Mixer

Intermeshing Dispersion Kneading MixerIntermeshing Dispersion Kneader



Specifications of LINA Intermeshing Dispersion Kneader


LN Dispersion Kneader

Type

Size

Dimension (mm)

Weight (kg)

LN-LAB TEST (LT) kneader

0.5

1600*900*1900

800

1

1600*900*1900

800

2

1600*900*2000

900

3

1600*900*2100

900

5

1900*1000*2100

1200

10

2200*1350*2150

2500

LN-Mass Production

15

2200*1350*2150

4000

20

2500*1450*2450

3800

25

2500*1500*2500

4500

35

3200*1900*3000

6500

55

3300*2000*3100

7800

75

3800*2300*3200

10800

110

4100*2300*3400

16500


Intermeshing Type Dispersion Kneader

Intermeshing Type Dispersion Kneader,Intermeshing Kneader For Rubber Mixing,Rubber Intermeshing Type Kneader

LINA Machinery Industrial Co.,Ltd , http://www.linakneader.com