New Hot Sale Portable Ultrasonic Flowmeter (A+E-80FC)
Chocolate Ball Milling Machine
500kg Chocolate Ball Milling Machine is used for ball milling chocolate pastes. It has the advantages of high production output, low energy cost, even fineness and etc..This machine can be used along with conche or mixer, storage tank and chocolate delivery pumps to ensure continuous production and improve production efficiency.It has automatic temperature control.
Three models of chocolate ball milling machine:
Model
QMJ250
QMJ500
QMJ1000
Main Motor Power(kw)
15
44
55
Biaxial Revolution Speed
(rmp/Variable Frequency Control)
250-500
250-500
70-170
Production Capaction(kg/h)
200-250
300-500
750-1000
Fineness(um)
25-20
25-20
25-20
Ball Material
Ball Bearing Steel
Ball Bearing Steel
Ball Bearing Steel
Balls Weight(kg)
180
460
1400
Machine Weight(kg)
2000
2750
5000
Outside Dimension(mm)
1100*1250*2150
1200*1450* 2250
2400*1500*2600
Chocolate Ball Milling Machine,Ball Mill Machine For Chocolate,Chocolate Ball Miller,Ball Mill Chocolate Machine Suzhou Lejoy Machinery Co., Ltd. , https://www.choco-machine.com
The flow meter is a portable clamp-on flow meter with built-in printer offering
a variety of optional features. It is a compact and robust instrument that
comprises additional functions that can turn it into more than just a flow meter.
General Information for Ultrasonic Flowmeter
In contrast to its hand-held couterpart, the portable flow meter offers a built-in
thermosensitive printer to relize real-time or definite time printing. But it can't beÂ
used simultaneously with data logger function.
The correct installation of the clamp-on sensors on the pipe is made easy by the
incorporated Audibel Sensor Positioning Assistant which gives the user visual and
audible indications during sensor mounting.
Heat quantity measurement for Ultrasonic Flowmeter
The portable flow meter offers a heat quantity measurement function that turns the
instrument into a portable energy meter. When equipped with this feature, the meter
incorporates measured flow and temperature values delivered by two PT100 sensors
into heat flow and heat quantity. This is valuable information to assess the efficiency
of heat exchangers and HVAC systems.
Data logger and download interface for Ultrasonic Flowmeter
The flow meter can be ordered with an internal data logger, which is available to
store up to 100,000 measurements with each measurement ( volume, mass, heat
flow, heat quantity and temperature units) which can be selected by the user before
each measurement. The data can be transferred via RS 232 or USB.
Measurement technology for Ultrasonic Flowmeter
All AEAD clamp-on ultrasonic flow meters apply ultrasonic transit-time measurement
technology. This enables the instruments to provide highly accurate and reliable flow
data for almost any kind of liquid regardless of its electric conductivity.
This portable ultrasonic flow meter is widely used to measure water, seawater, sewage,
alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic
ave.
Technical Parameters for Ultrasonic Flowmeter
1. Flow Measurement Accuracy:Â better than 1%
2. Calorimetric Measurement Accuracy: 2%-3%
3. Working Power Supply: built-in Ni-MH rechargebale battery,
   charging source 220V, which supplies for up to 24 hours after charging.
4. Measuring Period: 500ms (2 times per second, and 128 groups of data
   collected during each period)
5. Display Digits: 8 digits, 2 lines of Chinese character displayed on the same screen.
6. Thermal Loss Calculation:Â beginning with 0.25K, temperature resolution: 0.01 degree
7. Temperature Range: 4 degree ~ 95 degree, temperature difference range:3 degree ~ 75 degree
8. Ambient Temperature: category B, -25 degree ~ 55 degree
9. Signal output: isolated RS485
10. Communication Protocol:Â Â MODBUS protocol, FUJI extension protocol and
     compatible with the communication protocols of similar products manufactured in
     other venders at home.
11. Printout:Â Â equipped with built-in integrated thermal printer, which can realize real-time
     or timed printing.
12. Data Storage:Â the optional built-in data storage unit (SD card) can store
     time, instantaneous flow, accumulative flow, signal status and etc. The data can be imported
     into the computer (only one from data storage and printing functions can be selected).
13. Installation: external application installation
14. Temperature Sensor: PT100 Jacketed platinum resistor
15. Other Functions:Â Â self diagnosis to indicate whether the current working condition is normal or not.
Technical parameters:
Standard S1 type
Standard M1 type
Standard L1 type
High-temperature S1H type
High-temperature M1H type
Applicable pipe diameter (DN)
15~100
50~700
300~6000
15~100
50~700
Material
ABS
Special high-temperature material
Working frequency
IMHZ
Installation method
V (N\W)method
V\Z method
Z method
V (N\W)method
V\Z method
Calibration
Pairing & Calibrating for the complete machine
Magnetism
Yes
N/A
Applicable temperature
0~70 degree
0~160 degree
Protection grade:
IP65
Dimensions
45×30×30
60×45×45
80×70×55
90×85×24
90×82×29
Mass (gram)
75
250
650
94
150
Medium type:
Water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic wave
Medium turbidity:
≤20000ppm with low bubble content
Applicable pipes:
Uniform and compact pipes made of carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastics, and lining is permitted.
Pipe lining material
Epoxy asphalt, rubber,
mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc.
Signal cable
Standard configuration: 5mX2, and 10mX2 or 15mX2 are optional.
Usage & Specification: