Application Analysis of Laboratory Ion Chromatograph
Ningbo Senmiao Trading Co., Ltd. , https://www.senmiaowasher.com
Characteristics of Ion Chromatography Methods Determination of ionic compounds is the main content of classical analytical chemistry. There are some rapid and sensitive analytical methods for the analysis of cations, such as atomic absorption, high-frequency inductively coupled plasma emission spectroscopy, and X-ray fluorescence analysis. The analysis of anions has long lacked a rapid and sensitive method. The classic volumetric, gravimetric and photometric methods have been used. These method steps are lengthy, time-consuming, sensitive, and susceptible to interference. The developed ion chromatography overcomes the above drawbacks and has the advantages of rapidity, high sensitivity, good selectivity, and the ability to measure multiple components simultaneously. It can be said that the analysis of anions by ion chromatography is a new breakthrough in analytical chemistry.
Fast and convenient analysis of seven common anions (F-, Cl-, Br-, NO3-, NO2-, SO42-, PO43-) and six common cations (Li, Na, NH4, K, Mg2, Ca2) The time is less than 10min. For example, the separation time of the above-mentioned seven common anions can be as short as 3 minutes.
The high sensitivity of the ion chromatography ranged from μg/L to mg/L. When the injection volume was 50 μl, the detection limit of common anions was less than 10 μg/L. If you increase the injection volume and use a small aperture column (2mm diameter) or online concentration, the detection limit can reach 10-12g/L.
Selective IC methods for the analysis of the selectivity of inorganic and organic cations and cations are mainly achieved by the selection of appropriate separation and detection systems. Due to the selectivity of the IC, the pretreatment of the sample is simple, and dilution and filtration are generally required.
Simultaneous determination of multiple ionic compounds Compared to photometric, atomic absorption methods, the main advantage of ICs is the simultaneous detection of multiple components in a sample in a short time.
Separation column with good stability, high capacity IC styrene / divinylbenzene polymer is the most widely used filler. The high pH stability of this resin allows the use of strong acids or alkalis as eluents, which is beneficial for expanding the range of applications. Dissolving, diluting, and filtering are the main tasks of pretreatment when analyzing samples.