Three Phase Close-Link Kwh/Electric/Energy Meter Test Bench with Isolated CT (PTC-8320E)
Hydraulic Oil Cylinder,Hob Heavy Oil Cylinder,Heavy Duty Hydraulic Oil Cylinder,Heavy Standard Hydraulic Oil Cylinder Dongguan Jinzhuang Hydraulic Technology Co., Ltd. , https://www.jinzhuanghydraulic.com
2. Specification
2.1 Accuracy class: 0.05/0.1 class
2.2 Reference standard meter:Â
HC3100H  Accuracy class: 0.02
HC 3100A  Accuracy class: 0.05/0.1
2.3  Isolated current transformer equipment: Â
PTC-9503B insulate current inductance
Accuracy class:0.1(COSφ=0.5C-1-0.5L,0.1-100A) (200A optional)
Output power:30VA(MAX,100A)
2.4 Voltage amplifier:
Output voltage range: 30-400V (phase-neutral)
                                50-600V (phase-phase)
             Output power: ≥15VA(every meter)
Resolution:Â 0.01%
Stability: better than 0.05%/180sÂ
Distortion factor: < 0.5% at linear load
Frequency range: 45Hz~65Hz
Power efficiency: more than 85%
Ambient temperature:10ºC~50ºC
 2.5 Current amplifier:
Output current: range: 1mA~100A (200A optional)
Output  power: ≥40VA(every meter)
Resolution:Â 0.01%
Stability: better than 0.05%/180sÂ
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: greater than 85%;
Ambient temperature:10ºC~50ºC
2.6 Phase Angle: 0°~360° , resolution of phase angle setting: 0.1°;
2.7 Output frequency range: 45Hz~65Hz; resolution: 0.01Hz
2.8 Harmonic wave output:
   2-21 sub-harmonic wave contents=40%
   3,5,7 sub-harmonic wave couping, total content=40%
      Phase angel control (odd sub-harmonic wave)
           Wave group control (sub-harmonic wave)
2.9 Output stability of power: <0.05% (180s)
2.10 Numbers of calibrated energy meter: 16
2.11Input power: AC3x220/380V(Y) 15%, 50/60Hz
1.Features
1.1 The bench accords with the standard of "IEC 60736:1982Â
Testing equipment for electrical energy meters", "IEC 62053"
1.2 Close-link and ordinary calibration both can be used, ordinary
calibration can be used to test single/three phase active andÂ
reactive energy meter(up to 0.5 class),close-link calibration can beÂ
used to test single/three phase active and reactive energy meter(upÂ
to 1 class).
Â
Â
1.3The bench can test the converted quantity which is caused byÂ
negative phase, voltage unbalance, harmonic wave and so on.
1.4 The bench can auto-calibrate starting, no load, basic error and
calibration tolerance and 24h deflection.
1.5 Close-link calibration is using insulate current transformer and
suitable for close-link energy meter.
1.6 The bench is using the error processor system to calculate theÂ
error of each energy meter by the sub-error system which can beÂ
connected by the internal RS485.
1.7 The same specification but different constant energy meter canÂ
be tested at one time.
1.8For the installed pick-up equipment, can offer 3 rangesÂ
adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter.
1.9 The bench can choose to operate by keyboard or PC which is
convenient. The working status of bench can be seen very clearÂ
and easy operation.
1.10 The bench is using the testing software complied with
WINDOWS98/2000/XP which can auto-testing different energyÂ
meters.Â
1.11 The software can realize the data from energy meter forÂ
statistics, search and management. It also can connect with on-lineÂ
management for up load the data.
1.12 The energy meter hanging rack is made by AluminumÂ
compound.The whole device configuration is a reasonable designÂ
and nice outfit.
Â