100kw-2000kw Googol Marine Diesel Genset with CCS
Multifunctional Hoists,Hoist Weight Machine,Material Hoisting Equipment,Hoisting Equipment Machines Jiangsu Minnuo Group Co.,Ltd , https://www.js-minnuomachinery.com
Marine Series Generators 130KW
Engine brand: Cummins, Deutz, Lovol
Alternator: Stamford, Leroy Somer, Marathon
Certification: CCS or according to required
Cooling Type: Radiator of Sea Water Pump with heat exchanger.
Marine Diesel Generating Sets are suitable for sea areas as draining water ship, tugboat, fishnet ship, freighter and digging-ship etc as electric power supply and can be used as Marine Main ower Generator, Marine emergency Power Generator or Harbor Generator.
Honny Power Marine diesel generator set (ship's auxiliary equipment), with over 20 years of development and research, we can provide high-quality and pollution-free marine power generators to clients all over the world. The power scope is from 10kW to 1800kW, which can be powered by Famous marine diesel engines of Cummins, Deutz MWM, Volvo Penta, and SDEC Series and coupled with Stamford, Siemens or Marathon alternators. Until now, our marine gensets have been widely used as main power source or emergency power source of all kinds of boats, such as various kinds of large ships yards, river navigation fishing boat, transport ship, luxurious yachts and so on.
Cummins Marine Generator from 20kva upto 1000kva.
SDEC Marine Generator from 50kva upto 562kva.
Volvo Penta Marine Generator from 100kva upto 800kva.
As to the certificates, Ettes power will supply CCS as standard. And we also can supply ABS, BV, DNV or LRS Certificates for clients' option according to their special requirements, which can provide a reliable guarantee for your ship and equipments, Ettes Power'smarine genset is one of your best choices in selecting auxiliary equipment for all kinds of ships.
Standard supply scope of Ettes Power Marine diesel generator: Complete marine diesel genset including marine diesel engine, alternator, base frame, heat exchanger, standard control system, radiator (optional), soundproof canopy (optional equipments for emergencymarine diesel generator set), certificates, user books and other accessories.
Please click here to read more about Ettes Power Marine diesel generator sold to international market since recent years.
Tags: Marine Generator, Marine diesel generator, marine generator set, marine diesel generating set, marine diesel generator set
Engine Model
Â
PTA780-M1
Engine Model
rpm
1500
 Rating Output
Â
Â
Engine Standby Output ( LTP)
kW
360Â
Engine Prime Output (PRP)
kW
330Â
Engine Continuous Power (COP)
kW
300Â
Standby Output's Torque
. ( N.M )
2292Â
Prime Output's Torque
. ( N.M )
2101Â
Continuous Output's Torque
. ( N.M )
1910Â
BMEP for Standby OutputÂ
bar
22.48Â
BMEP for Prime OutputÂ
bar
20.60Â
BMEP for Continuous Output
bar
18.72Â
Speed droop (static) elect. Gov.
Â
0-5%
Max. step load acceptance, 1st step ( % Prime Output )
Â
65%
Â
Â
Â
Basic Performance Datasheet
Â
Â
Aspiration Type
Â
Turbocharger, air-water aftercooler
Injection Type
Â
Direct Injection
Configuration
Â
In line
No. of Cylinders
Â
6
DisplacementÂ
l
12.8
BoreÂ
mm
128
StrokeÂ
mm
166
Compression Ratio
Â
15.5:1
Piston SpeedÂ
m/s
8.3
Rotation Direction (from flywheel)
Â
Counter Clockwise
Number of Flywheel TeethÂ
Â
160Â
Flywheel House Size
Â
SAE1-14
Lubrication System
Â
Â
Lube Oil Specification
Â
API-CF4
Oil CapacityÂ
l
40
Max. Permissible Oil TemperatureÂ
°C
110
Low Oil Pressure WarningÂ
kPa
200
Low Oil Pressure ShutdownÂ
kPa
160
Oil consumption (as % of fuel consumption)
max
0.5Â
Cooling System
Â
Â
Coolant Capacity for EngineÂ
l
18
Max. Permissible Temperature Â
°C
90
Max. Coolant Warning Temperature Â
°C
95
Max. Coolant Shutdown Temperature Â
°C
105
Thermostat Open TemperatureÂ
°C
82
Flow of Coolant pumpÂ
m³/h
19.7
Heat dissipation (engine radiator)
kW
173Â
Heat dissipation (CAC)
kW
*
Heat dissipation (convection)
kW
26Â
Fuel System
Â
Â
Governor Type
Â
ElectricalÂ
Engine Output at prime output
kW
330Â
Fuel Consumption at 25% of  prime output
l/h
26.69Â
Fuel Consumption at 50% of prime output
l/h
44.49Â
Fuel Consumption at 75% of prime output
l/h
61.88Â
Fuel Consumption at 100% of prime output
l/h
80.88Â
Lowest Fuel Consumption Ratio
g/kW.hr
204.66Â
Intake & Exhaust System ( On standby Output )
Â
Â
Combustion Air ConsumptionÂ
m³/min
27.00Â
Max. Intake RestrictionÂ
KPa
5
Max. Exhaust Temperature (Before Turbo)
°C
625
Max. Exhaust Temperature (After Turbo)
°C
485
Max. Exhaust Back Pressure
Kpa
5
Exhaust Gas Flow Â
m³/min
33.00Â
Exhaust Flange DiameterÂ
mm
125
Electrical System
Â
Â
Charging Alternator VoltageÂ
V
28
Charging Alternator CapacityÂ
A
35
Starting VoltageÂ
V
24
Starting Motor CapacityÂ
kW
6.6
Minimum Battery CapacityÂ
Ah
2*150
Quantity of generator set's Bearing (( For 400-660VAC generator )
Â
1
Quantity of generator set's Bearing (( For Above 3300VAC generator )
Â
2
Engine Dimension
Â
Â
LengthÂ
mm
1745
WidthÂ
mm
900
HeightÂ
mm
1196
Engine Dry Weight w/o Cooling System
kg
1125